Identification of Penicillinase-Resistant Penicillins in Human Urine by RPLC Method
Keywords:
combined effect, penicillinase-resistant penicillins, method validation, internal standard, human urineAbstract
In this study, the combined effect of the organic modifier content and mobile phase pH has
been used to predict the chromatographic behavior of methicillin, oxacillin, nafcillin,
cloxacilin and dicloxacillin. The optimum separation condition of these drugs in acetonitrilewater binary mixture was determined from the mobile phase pH dependence of their
retention factor. A Synergy Fusion-RP C18 analytical column (150 mm x 4.6 mm I.D., 4 µm)
was preferred to carry out the developed method. Chromatographic measurements were
done at 30◦C with an eluent flow rate of 1 mL min-1
. In order to validate the optimized
conditions, these drugs were applied successfully in spiked samples of human urine.
Valsartan was chosen as an internal standard. The described method was linear over a
concentration range of 2-32 µg mL-1 and 3-48 µg mL-1 for the assay of methicillin, nafcillin,
dicloxacillin and oxacillin, cloxacillin respectively. Good linear relationships over the
investigated concentration ranges were observed with values of correlation coefficient
higher than 0.999 for all of the drugs. The intra-day and inter-day precisions of this method
were evaluated with RSD (%) values less than 0,561 and 1,622%, respectively. Optimized
assay method was validated according to United States Pharmacopeia (USP) guidelines to
confirm linearity, accuracy and precision.